You are not registered yet. Please click here to register!
LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key - i4memory.com - different look at memory

Notices

Rate this Entry

LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key

Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to Digg Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to del.icio.us Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to StumbleUpon Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to Google Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to Yahoo Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to Facebook Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to Reddit Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to Slashdot Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to MySpace Submit "LSI MegaRAID Battery Backup Unit LSIiBBU07 & LSI Fastpath Key" to Twitter
Posted 13-09-2010 at 05:10 PM by eva2000
Updated 13-09-2010 at 06:26 PM by eva2000

New hardware arrived LSI MegaRAID LSIiBBU07 Battery Backup Unit (BBU) for 8880EM2, 9260-xx and 9280-xx and LSI MegaRAID Fastpath key for my LSI MegaRaid 9260-8i unit.

The LSI LSIiBBU07 BBU is meant to provide at least 72hrs of battery backup in case of power outage. But user reports have the BBU providing as much as 130 hrs. Apparently, the BBU has a learning cycle for 24-48hrs after first use which happens after the initial automated discharge and recharge cycle within the first 4hrs of powering on the BBU unit. It does this learning cycle once every month but can be disabled within web bios at the expense of reducing battery useful lifetime though. So during this learning cycle, the BBU will report to be disabled so you won't be able to properly select Write through cache with BBU until the the learning cycle is complete.

Quote:
LSI MegaRAID FastPath software provides a high performance I/O accelerator, designed to substantially boost transactional application throughput of multiple SSDs connected to a 6Gb/s SATA+SAS MegaRAID controller. MegaRAID FastPath supports full optimization of SSD Virtual Disk groups to deliver up to 2X improvement in read and write I/Os per second (IOPS) compared to the previous generation product.

Benefits:
  • Provides high-performance I/O acceleration for SSDs connected to a 6Gb/s MegaRAID SATA+SAS controller.
  • Designed to substantially boost transactional application throughput, delivering up to 150,000 IOPs
  • Supports full optimization of SSD virtual disk groups to deliver up to a 2X improvement in read and write IOPs compared to MegaRAID controllers not utilizing MegaRAID FastPath software.
  • Performance levels reached with this solution are equivalent to those of much costlier Flash-based adapter card solutions.